Anderson-Snow
Call now
Call now
Website
Call
Anderson-Snow
Since 1954, ANSCOR has been meeting the needs and special requirements of our customers, fabricating a complete line of custom and heavy duty finned tube coils. We're your ultimate source for industrial heating & cooling coils that can be used for new installations and retrofit. Today, we're recognized throughout the industry for our value, quality, and prompt delivery.

I've tried other " Industrial Heavy Duty " coils only to find out they they are nothing more that standard HVAC coils with a slightly heavier tube. Anderson-Snow solved my coil problems by actually supplying all welded, carbon & stainless coils. Coils that I can be use in my process equipment without failing. Anderson Snow came out and field measured my coils to insure an exact dimensional replacement.

They replaced my copper tube brazed coils with all welded stainless coils. With the same fin material there was no loss in heat transfer and now I do not have to replace my dryer coils every 2-3 years.
Services
Since 1954, Anderson-Snow Corporation has served the chemical, food, oil and gas, pharmaceutical, pulp and paper, utility, and general industrial markets manufacturing the highest quality coils.
We pride ourselves on providing effective solutions to meet the special requirements of our customers by fabricating a complete line of custom industrial grade finned tube coils.
ANSCOR designs and manufactures coils for new installations, for wide ranges of applications, from industrial process to HVAC comfort conditioning.
Booster Coils are used for zone heating or individual room heating where small hot water or steam coils are required.
Serpentine Coils can be used for Low-Pressure Modulated Steam provided noise is not a factor.
If noise is objectionable, use Standard Blast Coils with Opposite-End Connections.
Vacuum Breakers should be used with Booster Steam Coils and All Other Types of Steam Coils.
See Anderson-Snow Vacuum Breaker Sheet for Use and Installation of Vacuum Breakers.
Overall casing dimensions will match your original unit, regardless of size or type of metal.
As the leader in custom, replacement and special application heating and cooling coils, Anderson - Snow will improve casing design, simplify installation in an existing space and duplicate or adjust connection sizes and positions when necessary.
ANSCOR has not departed from the industry's time-proven heavy wall copper construction.
Under normal conditions, standard ANSCOR coils should last 20 years.
Using extra heavy tubing, copper fins and stainless steel casing, the life expectancy could be up to 40 years.
ANDERSON - SNOW Corporation engineers are experienced in solving steam coil problems.
Proper drainage, trapping and piping are essential for long coil life.
We will gladly assist you with such problems and can fabricate specially designed coils for unusual applications or for the replacement of any existing coil.
EXCELLENT CONDENSATE DRAINAGE is provided due to the large area between the inner steam distributing tube and the outer condensing tube, in combination with the pitched tubes.
Standard coils are guaranteed for working pressures up to 150 PSIG and 366 degrees fahrenheit.
A special light tension spring, which senses even the slightest vacuum forming in your coil, will open, break the vacuum and drain the coil.
Thus preventing freeze-up and other costly damage.
Leakage rate: Metal-to-Metal seal between valve disc and set is super-lapped to effect gas tightness in accordance with ANSI B147.1.
Reviews
Review Anderson-Snow

Be the first to review Anderson-Snow.

Write a Review